Furniture Structural Testing >> BIFMA X5.9-2012 Storage Units - Tests

BIFMA X5.9-2012 Storage Units - Tests

BIFMA X5.9-2012 Tests

  • Section 4 - Unit Strength Test
  • Section 5 - Leg/Glide Assembly Strength Test
  • Section 6 - Racking Resistance Test
  • Section 7 - Vertical Load Durability Tests
    • 7.1 - Top Load Ease Cycle Test
    • 7.2 - Drop Test - Dynamic - for Units with Seat Surfaces
    • 7.3 - Durability Test for Units with Seating Surfaces - Cyclic Impact
  • Section 8 - Separation and Disengagement Tests
    • 8.1 - Separation Test for Tall Storage Units w/ Vertically Attached or Stackable Components
    • 8.2 - Upward Impact Force Disengagement Test for Storage Units
    • 8.3 - Upward Force Static Disengagement Test for Storage Units
  • Section 9 - Stability Tests 9.1 Purpose of Tests
    • 9.2 - Horizontal Force Stability Test for Tall Storage Units
    • 9.3 - Stability Test for Type l Units with at least one Extendible Element
    • 9.4 - Stability Test for Type l Storage Units with Multiple Extendible Elements
    • 9.5 - Stability Test for Type ll Storage Units having Extendible Elements
    • 9.6 - Vertical Force Stability Test for Storage Units
    • 9.7 - Stability Test for Pedestals/Storage Units with Seat Surfaces
  • Section 10 - Storage Unit Drop Test
  • Section 11 - Movement Durability Test for Mobile Storage Units
  • Section 12 - Rebound Test
  • Section 13 - Extendible Element Retention Impact and Durability (Out Stop) Tests
  • Section 14 - Lock Tests
    • 14.2 - Force Test for Extendible Element Locks
    • 14.3 - Force Test for Door Locks
    • 14.4 - Locking Mechanism Cycle Test
  • Section 15 - Extendible Element Cycle Tests
    • 15.2 - Cycle Tests for Extendible Elements Deeper than Wide that Do Not Swivel
    • 15.3 - Cycle Tests for Extendible Elements Wider than Deep that Do Not Swivel
    • 15.4 - Horizontal Cycle Test for Television/Video Display Terminal Extendible Elements
    • 15.5 - Cycle Test for Low Height Drawers
  • Section 16 - Interlock Strength Test
  • Section 17 - Door Tests
    • 17.2 - Strength Test for Vertically Hinged, Bi-fold, and Vertically Receding Doors
    • 17.3 - Hinge Override Test for Vertically Hinged Doors
    • 17.4 - Vertical Receding Doors Strength Test
    • 17.5 - Horizontal Receding Doors Strength Test
    • 17.6 - Wear and Fatigue Tests for Hinged, Horizontally Sliding, and Tambour Doors
    • 17.7 - Wear and Fatigue Test for Vertical Receding Door
    • 17.8 - Wear and Fatigue Test for Horizontal Receding Door
    • 17.9 - Vertical and Horizontal Receding Door Out Stop Test - Cyclic Impact & Durability
    • 17.10 - Slam Closed Test for Vertically Hinged and Vertically Receding Doors
    • 17.11 - Drop Test for Horizontally Hinged and Horizontally Receding Doors - Cyclic
    • 17.12 - Slam Test for Doors which Free Fall Open or Closed
    • 17.13 - Slam Open and Closed Test for Doors which Do Not Free Fall
    • 17.14 - Door Latch Test
  • Section 18- Clothes Rail Static Loading Test
  • Section 19 - Swivel Cycle Test for Television/Video Display Terminal Surfaces
  • Section 20 - Pull Force Test

If there is a test you require that is not listed, please call our Product Development Specialists: Seth Setzer at 828.327.7000 x 4449 or e-mail: Seth Setzer or Cody Whitener at 828.327.7000 x 4490 or email: Cody Whitener